UniMed — IVF & Embryology Solutions

Series: MIRI®

Esco Lifesciences

MIRI® GA Gas and Temp. Validation Unit

Continuous CO₂, O₂, and temperature validation for IVF incubators

Gas & Temperature Analysis & MonitoringMonitoring & validationEquipment
Model:
MRI-GA
Item code:
1320045
MIRI® GA Gas and Temp. Validation Unit — 1MIRI® GA Gas and Temp. Validation Unit — 2MIRI® GA Gas and Temp. Validation Unit — 3MIRI® GA Gas and Temp. Validation Unit — 41 / 4

Specifications

Model
MRI-GA
Item code
1320045

Order codes (9)

Dimensions (W × D × H)
355 × 360 × 140 mm
Weight
8 kg
Power
45 W · 115/230 V medical grade
Temperature range
30.0 – 39.9 °C

Includes data logger software, 1× PT1000 cable, 1× gas connection tube, 1× gas feedback tube. Accessories: sets of 6 cables/tubes (MRA-1102, MRA-1104).

Specifications

Model
MRI-GA
Item code
1320045
Dimensions (W × D × H)
355 × 360 × 140 mm
Weight
8 kg
Power
45 W · 115/230 V medical grade
Temperature range
30.0 – 39.9 °C
CO₂ range
2.8 – 10.0% (NDIR dual beam)
O₂ range
2.8 – 20.0% (electrochemical)
Gas sample ports
6 (auto switch 30 s / 1 / 5 min)
PT-1000 inputs
6 with auto detection
Flow rate
0 – 5 L/h user set

Workflow: Embryo Culture · Quality Control

Overview

MIRI® GA is a tabletop gas and temperature validation device for continuous external QC of IVF incubators — including MIRI® Time-Lapse, MIRI® Multiroom, Mini MIRI®, and other brands. It measures temperature and gas concentration at the same time (unlike separate handheld units), runs 24/7 with adjustable 0–5 L/h suction (~3 L/h typical vs up to 12 L/h on conventional validators), and logs data with configurable e-mail alarms. Six gas sample ports and six PT-1000 inputs allow automatic switching between chambers (30 s, 1 min, or 5 min intervals). When connected to MIRI® incubators, a gas feedback loop can form a closed system to reduce leakage and waste; non-MIRI units may exhaust to a dedicated outlet. Windows data logger software (Vista and above) runs on a separate PC — not required inside the GA — for monitoring, recording, and alarm notification.

Applications

  • Continuous incubator gas and temperature validation
  • QC documentation for IVF and ART laboratories
  • Multi-chamber MIRI® and third-party incubator monitoring

Product features

Simultaneous gas and temperature

One device replaces separate handheld CO₂/O₂ and temperature validators for efficient QC.

Continuous 24-hour monitoring

Always-on measurement versus interval spot checks with portable units.

Six-chamber capability

Validate up to six incubation chambers with automatic port switching.

Gentle adjustable flow

User-set 0–5 L/h suction reduces gas waste compared with high-flow portable devices.

Data logger with e-mail alarms

Windows software records parameters and sends alerts when thresholds are exceeded.

MIRI® gas feedback loop

Optional closed-loop connection to MIRI® incubators minimizes leakage and gas consumption.

Related Products

DropX Analyst — 1DropX Analyst — 2DropX Analyst — 3DropX Analyst — 4DropX Analyst — 5DropX Analyst — 6DropX Analyst — 7DropX Analyst — 8DropX Analyst — 9DropX Analyst — 10DropX Analyst — 11DropX Analyst — 12DropX Analyst — 13DropX Analyst — 14DropX Analyst — 15DropX Analyst — 16DropX Analyst — 17DropX Analyst — 18DropX Analyst — 19
Equipment

IVF Prime

DropX Analyst